FinalCommercialRepair
Electrical Permit
#2025-119232 EP
Electrical Permit - Repair
📋 Project Description
Extended Electrical Conduit and Conductors to relocate a light fixture. Work Description: Utilize existing light circuit with wall switch. Extend circuit ~8 feet so chandelier can be centered in the building. Install 12 AWG THHN copper conductors (Hot Neutral Ground). Run conductors in 3/4¿ metal conduit with metallic fittings for fire protection. Provide and install listed ceiling box/support rated for ¿50 lbs (fixture is ~10 lbs). Mount chandelier per manufacturer¿s instructions. Bond all metal components to equipment grounding conductor. Test for continuity grounding and correct polarity. Update panel schedule to reflect new fixture location.
📍 Project Location
Job Site Address
3701 GROOMS ST BLDG A, Austin, TX
🔧 Work Details
Work Class
Repair
Permit Type
Electrical Permit
Permit Class
Commercial
👷 Contractor Information
📅 Timeline
Applied Date
N/A
Issued Date
Oct 13, 2025
Expiration Date
N/A