๐ŸProject Closed๐Ÿ”ง Renovation/Alteration๐Ÿ’ต This project is privately funded, on private land for private use.

Nvidia - Austin 2/F Security Updates

11001 Lakeline Blvd Building 2, Level 2, Austin, TX 78717, Austin, TX, 78717
Completed100%

๐Ÿ“ŠProject Metrics

TDLR #TABS2024014080
$111K
Project Value
692
Square Feet
$160/sqft
Cost/SqFt
7 months
Duration
Registered:Mar 18, 2024
Start:Jun 10, 2024
Target:Dec 31, 2024
๐Ÿ

Project Closed

Project has been completed and closed

๐Ÿ“‹Scope of Work

Minor renovation to accommodate new security updates for Level 2.

Note: This project is registered under the Texas Accessibility Standards (TAS) program. TDLR registration is required for commercial and public facility construction to ensure compliance with accessibility requirements under Texas Government Code Chapter 469.

๐Ÿ“…Compliance Timeline

Project Registered
March 18, 2024
Project Closed
December 31, 2024
Construction Start
June 10, 2024
Expected Completion
December 31, 2024

๐Ÿ“„Related City Permits

Building permits found at or near this location

11001 LAKELINE BLVD BLDG 1 UNIT 300

Interior Remodel for Existing Office - Suite 300

ActivePlumbing PermitRemodelFeb 2026
View Details
2026-022123 PP
๐Ÿ”งKilgore Industries
11001 LAKELINE BLVD BLDG 1 UNIT 300

Interior Remodel for Existing Office - Suite 300

ActiveBuilding PermitRemodelFeb 2026
View Details
2026-022123 BP
๐Ÿ”งNovo Construction **Main**
11001 CAP STONE DR

Re-route three romex wires and an outlet in a 53 long section of nonstructural interior wall that is being moved 5 inches. A 42(H) x 54(W) section of sheetrock will be removed exposing the entire lengths of the wires that need rerouting. The existing wall is a 42 high nonstructural half-height wall made of two 2x4 frames parallel to one another and separated by approximately one inch of space (13.5 thick overall including sheetrock). The intent of the project is to remove the outer 2x4 frame reducing the thickness of the wall to only one 2x4 structure. The wires are routed through the outer frame so they need to be re-routed through the inner frame.

ActiveElectrical PermitRepairFeb 2026
View Details
2026-010937 EP
11001 LAKELINE BLVD BLDG 1

28347 Continental General - Illuminated Wall Sign

FinalElectrical PermitWallDec 2025
View Details
2025-158105 EP
11001 LAKELINE BLVD BLDG 1 UNIT 300

Interior non structural demolition