🏁Project Closed🔧 Renovation/Alteration💵 This project is privately funded, on private land for private use.

WHOLE FOODS MARKET PLAZA BARISTA

550 BOWIE STREET, Austin, TX 78703, Austin, TX, 78703
Completed100%

📊Project Metrics

TDLR #EABPRJB4806251
$100K
Project Value
Square Feet
Cost/SqFt
2 months
Duration
Registered:Dec 18, 2013
Start:Feb 1, 2014
Target:Apr 1, 2014
🏁

Project Closed

Project has been completed and closed

📋Scope of Work

renovation to plaza-level reception area

Note: This project is registered under the Texas Accessibility Standards (TAS) program. TDLR registration is required for commercial and public facility construction to ensure compliance with accessibility requirements under Texas Government Code Chapter 469.

📅Compliance Timeline

Project Registered
December 18, 2013
Project Closed
April 1, 2014
Construction Start
February 1, 2014
Expected Completion
April 1, 2014

📍Location & Views

Open in MapsGet Directions|30.27039, -97.75290

📄Related City Permits

Building permits found at or near this location

550 BOWIE ST
157 ft away

Interior - Lighting LED Upgrade (P2 & P3 Replace (320) 1x8x4-F32T8 fluorescent vaportite fixtures (112 input watts) and replace with 1x8 75W LED vaportite fixture with integral microwave occupancy sensor Retrofit (940) 1x4x1-F32T8 fluorescent wall wash strip fixtures (32 input watts) with 4⿿ 14W TLED ⿿Type B� ballast bypass lamps Retrofit(40) 1x3x1-F25T8 fluorescent wall wash strip fixtures (24 input watts) with 3⿿ 12W TLED ⿿Type B� ballast bypass lamps v (40) 1x2x1-F17T8 fluorescent wall wash strip fixtures (16 input watts) with 2⿿ 9W TLED ⿿Type B� ballast bypass lamps

FinalElectrical PermitUpgradeApr 2024
View Details
2024-045809 EP
🔧Facility Solutions Group
550 BOWIE ST UNIT 100
157 ft away

Work to take place in the parking garage not interior building. 1. Remove two-hundred and seventy (270) 1x8x4-F32T8 fluorescent vaportite fixtures (112 input watts) and replace with 1x8 75W LED vaportite fixture with integral microwave occupancy sensor (spec sheet attached). Color temperature is TBD. 2. Retrofit four hundred (400) 1x4x1-F32T8 fluorescent wall wash strip fixtures (32 input watts) with 4⿿ 14W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 3. Retrofit twenty (20) 1x3x1-F25T8 fluorescent wall wash strip fixtures (24 input watts) with 3⿿ 12W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 4. Retrofit twenty (20) 1x2x1-F17T8 fluorescent wall wash strip fixtures (16 input watts) with 2⿿ 9W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 5. Remove ten (10) 1x4x2-F32T8 fluorescent vaportite fixtures (58 input watts) and replace with 1x4 42W LED vaportite fixture with integral microwave occupancy sensor (spec sheet attached). Color temperature is TBD.

FinalElectrical PermitRepairOct 2023
View Details
2023-129853 EP
🔧Facility Solutions Group
550 BOWIE ST
157 ft away

Replacement of an existing water heater

FinalPlumbing PermitChange OutMar 2020
View Details
2020-039730 PP
550 BOWIE ST
157 ft away

interior alteration of approx. 1075sf of existing interior space

FinalMechanical PermitRemodelJan 2020
View Details
2019-230444 MP
🔧Air Craft Inc. Air Conditioning, Refrige
550 BOWIE ST
157 ft away

interior alteration of approx. 1075sf of existing interior space

FinalBuilding PermitRemodelJan 2020
View Details
2019-230444 BP
🔧Rand Construction Corporation