NAPA FLATS AT THE TRAILS
NAPA FLATS AT THE TRAILS is a new construction project at 8300 N. FM 620 BUILDING M, Austin, in Travis County, TX, tracked from its Texas Department of Licensing and Regulation (TDLR) registration. Construction complete (TDLR inspection passed Dec 2015). The project has an estimated value of $750K.
๐Project Metrics
TDLR #EABPRJB5814275Project Closed
Project has been completed and closed
NAPA FLATS AT THE TRAILS is a New Construction project located at 8300 N. FM 620 BUILDING M, Austin, TX 78726 in Austin, Texas. The project has an estimated value of $750K. CARR DEVELOPMENT is the property owner. The project was registered with TDLR on April 22, 2015.
โFrequently Asked Questions
What is NAPA FLATS AT THE TRAILS?
NAPA FLATS AT THE TRAILS is a new construction project at 8300 N. FM 620 BUILDING M in Austin, Texas, registered with the Texas Department of Licensing and Regulation (TDLR). Scope of work: Build our of new tenant shell space.
Is NAPA FLATS AT THE TRAILS open in Austin?
Construction on NAPA FLATS AT THE TRAILS is complete โ TDLR records show the project passed its required accessibility inspection in Dec 2015. The building is finished and very likely open.
Where is NAPA FLATS AT THE TRAILS located?
NAPA FLATS AT THE TRAILS is located at 8300 N. FM 620 BUILDING M, Austin, TX, 78726, in Travis County.
Who is the owner or developer of NAPA FLATS AT THE TRAILS?
CARR DEVELOPMENT is the property owner/developer of record for NAPA FLATS AT THE TRAILS, per its TDLR project registration.
How much does NAPA FLATS AT THE TRAILS cost and how big is it?
NAPA FLATS AT THE TRAILS has an estimated construction value of $750K, based on its TDLR filing.
๐Scope of Work
Build our of new tenant shell space.
Note: This project is registered under the Texas Accessibility Standards (TAS) program. TDLR registration is required for commercial and public facility construction to ensure compliance with accessibility requirements under Texas Government Code Chapter 469.
๐ Compliance Timeline
๐ Project Timeline
Filed
Apr 22, 2015
Review Complete
Inspection Complete
Closed
Dec 31, 2015
๐Related Projects
๐Nearby Projects
Within 1 km๐Related City Permits
Building permits found at or near this location
Addition of a rear patio cover - minor electrical
PROJECT SCOPE Provide one new dedicated AFCI/GFCI protected 20A 120V branch circuit from the main panel on the exterior wall of the house to a new kitchen range hood. No meter work being performed. INSTALLATION DETAILS Install a vertical 1-inch Steel EMT raceway exiting the main electrical panel from a 1-inch LR conduit body (located below all energized parts) on the homes exterior brick wall. Transition raceway to horizontal orientation for building penetration using a 1 LB. Penetrate into the accessible attic with 1 EMT terminating into a 4-11/16 steel junction box with a blank cover. Install #10-2 UF-B cable (1 HOT 1 NEUTRAL 1 EGC) (Sunlight Resistant/Wet Location rated) from the range hood to the steel junction box. Cable will be routed along ceiling rafters; any portion below 7 will be protected by guard strips per NEC 320.23. The #10-2 UF-B will be sleeved continuously from the 4-11/16 junction box through the LB down the vertical EMT and through the LR terminating directly into the main panel . This avoids all splices providing a continuous run from the OCPD to the appliance. CODE COMPLIANCE NOTES: 10 AWG conductors are specd. for this 20A circuit to account for ambient temperature correction in the unconditioned attic and sun-exposed exterior raceway. The EMT will be sealed with duct seal at the attic box and panel entry to prevent moisture migration and condensation per NEC 300.7. All cables and raceways will be supported/secured per NEC. All exterior fittings/hardware will be UL-listed rain-tight compression type. All cables and raceways will be supported and secured per NEC requirements. An insulated throat fitting or plastic bushing will be used at all EMT entry points to protect the cable jacket from abrasion. All wire terminations will be torqued to the manufacturer specifications per 2023 NEC 110.14(D)
Replacement of complete existing central heat and air system with or without duct work