Giving Home Health
📊Project Metrics
TDLR #TABS2026014592Project Registered
Project has been registered with TDLR and is in pre-construction phase
📋Scope of Work
Interior renovation of existing office space
Note: This project is registered under the Texas Accessibility Standards (TAS) program. TDLR registration is required for commercial and public facility construction to ensure compliance with accessibility requirements under Texas Government Code Chapter 469.
📅Compliance Timeline
🔗Related Projects
📄Related City Permits
Building permits found at or near this location
Constructing a partition around existing stair at floor 10 to prevent access
Construction of Partition around Existing Stair at Floor 11 to Prevent Access - Includes Installation of Steel bar Welded to Existing Guard Railing at Floor 10 to prevent access to Stair
Interior Remodel of Space Office for Suite 1410
Interior - Lighting LED Upgrade (P2 & P3 Replace (320) 1x8x4-F32T8 fluorescent vaportite fixtures (112 input watts) and replace with 1x8 75W LED vaportite fixture with integral microwave occupancy sensor Retrofit (940) 1x4x1-F32T8 fluorescent wall wash strip fixtures (32 input watts) with 4⿿ 14W TLED ⿿Type B� ballast bypass lamps Retrofit(40) 1x3x1-F25T8 fluorescent wall wash strip fixtures (24 input watts) with 3⿿ 12W TLED ⿿Type B� ballast bypass lamps v (40) 1x2x1-F17T8 fluorescent wall wash strip fixtures (16 input watts) with 2⿿ 9W TLED ⿿Type B� ballast bypass lamps
Work to take place in the parking garage not interior building. 1. Remove two-hundred and seventy (270) 1x8x4-F32T8 fluorescent vaportite fixtures (112 input watts) and replace with 1x8 75W LED vaportite fixture with integral microwave occupancy sensor (spec sheet attached). Color temperature is TBD. 2. Retrofit four hundred (400) 1x4x1-F32T8 fluorescent wall wash strip fixtures (32 input watts) with 4⿿ 14W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 3. Retrofit twenty (20) 1x3x1-F25T8 fluorescent wall wash strip fixtures (24 input watts) with 3⿿ 12W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 4. Retrofit twenty (20) 1x2x1-F17T8 fluorescent wall wash strip fixtures (16 input watts) with 2⿿ 9W TLED ⿿Type B� ballast bypass lamps (spec sheet attached). Color temperature is TBD. 5. Remove ten (10) 1x4x2-F32T8 fluorescent vaportite fixtures (58 input watts) and replace with 1x4 42W LED vaportite fixture with integral microwave occupancy sensor (spec sheet attached). Color temperature is TBD.
📐Related Site Plans
City of Austin site plan approvals at this location